PlcmRegistrationPolicyV2

PlcmRegistrationPolicyV2

you can specify policies to control registration by endpoint. Content-Type: application/vnd.plcm.plcm-registration-policy-v2+xml. All attributes are used in ETag calculation except for entity-tag and atom-links.


PlcmRegistrationPolicyV2 Fields

NameTypeDescriptionAttributes
compliantEndpointAdmissionPolicyPlcmRegistrationPolicyEnum
nonCompliantEndpointAdmissionPolicyPlcmRegistrationPolicyEnum
atomLinkList Array of LinkSee Definition of Link
registrationPolicyIdentifierstring The unique identifier of this registration policy. This a read-only field that is assigned by the DMA.
namestring The name of this registration policy. Mandatory
allowSiteLessRegistrationboolean If this option is selected, endpoints that don’t belong to a configured site or territory can register with the Call Server. Otherwise, only endpoints in a subnet configured in the site topology can register. Mandatory
includeChangedDevicesboolean Select whether to apply the registration policy script only to new registrations or also to changed re-registrations. Mandatory
ignoreIpAndPortsboolean Admin can optionally select Ignore IP and port changes so that the registration policy script is not applied.
deleteInactiveEndpointsboolean Select to specify that endpoints whose status is Inactive (that is, their registrations have expired) are deleted from the system after the specified number of days.Some dial rule actions, such as Resolve to registered endpoint, can route calls to endpoints with an inactive registration. Deleting the registration record is the only way to prevent resolution to an inactive endpoint. Mandatory
inactiveRegistrationDaysToDeleteint Select to specify that endpoints whose status is Inactive (that is, their registrations have expired) are deleted from the system after the specified number of days.Some dial rule actions, such as Resolve to registered endpoint, can route calls to endpoints with an inactive registration. Deleting the registration record is the only way to prevent resolution to an inactive endpoint.
entityTagEntityTag The unique value generated from the server object instance. This value is the same value that MUST be applied to the HTTP Entity Tag (ETag) header for a single instance of this object. Client modification of this field is not allowed for this instance.
registrationComplianceScriptstring This field will contains the registration policy script admin want to apply.
signalingPortsArray of SignalingPorts The signaling port assignments for this registration policy in the format: [h323 | sip]:<port>:[private | public]


Nested Types/Restrictions


NameTypeRestrictions
SignalingPortsstring
Length of value must be >=1
Length of value must be <=64
EntityTagstring
Length of value must be >=1
Length of value must be <=64